Floating Staircase Builders

Guide · Homeowners and Architects · 3 min read · Updated 17 November 2026

Floating Staircase Building Regulations: UK Rules Explained

Short answer

In England, private stairs must follow Approved Document K: a maximum rise of 220 mm, minimum going of 220 mm and maximum pitch of 42 degrees. Open risers must stop a 100 mm sphere passing through, with treads overlapping by at least 16 mm. Guarding must be at least 900 mm high, and headroom at least 2 metres, or 1.9 metres at the centre line in loft conversions.

Floating Staircase Building Regulations: UK Rules Explained

Why floating stairs need Building Control

Installing a new staircase is building work, and in England and Wales it must meet the Building Regulations. That means the design is checked by Building Control, either through the local authority or a registered building control approver, usually with drawings and structural calculations showing how the hidden steel or anchored treads carry the load. On completion, the work is inspected and a completion certificate issued. Keep that certificate, as solicitors ask for it when you sell.

Floating stairs attract particular attention because the structure is concealed and because open risers and open sides need careful detailing to be safe. A reputable installer will expect this process and build it into the programme and the price.

Replacing like-for-like parts of an existing staircase, such as a single tread, is usually treated as a repair. Removing a staircase and installing a new one is a different matter and should be treated as controlled work from the start.

Key dimensions for private stairs

Approved Document K sets the geometry for stairs in England. The figures below are for private stairs, meaning those serving a single dwelling. Every rise and going in a flight should be consistent, which is especially important on floating stairs where uneven steps are obvious and a trip hazard.

There is also a comfort rule: twice the rise plus the going should fall between 550 mm and 700 mm. A stair that meets the maximum rise and minimum going individually but falls outside this range will feel awkward to climb, so designers check both. For example, a rise of 190 mm and a going of 250 mm gives 630 mm, which sits comfortably in the range.

RequirementPrivate stair in EnglandNotes
Maximum rise220 mmRise is the vertical height of each step
Minimum going220 mmGoing is the horizontal depth from nosing to nosing
Maximum pitch42 degreesSteeper stairs are not allowed for private stairs
Open riser gap100 mm sphere must not passApplies between treads on open-riser stairs
Tread overlap on open risersAt least 16 mmEach tread overlaps the one below
Guarding heightAt least 900 mmMeasured from the pitch line
HeadroomAt least 2.0 m1.9 m at the centre line allowed for loft conversions

Open risers and the 100 mm rule

Most floating stairs have open risers, meaning there is no vertical board between treads. Approved Document K allows this for private stairs provided a 100 mm sphere cannot pass through the gap between treads, and each tread overlaps the one below by at least 16 mm. The 100 mm figure is there to stop a small child's head from passing through.

There are two common ways to comply. One is to use thick treads and set them so the gap is under 100 mm. The other is to add a discreet riser bar, glass upstand or steel rod between treads to close the gap. Designers usually choose tread thickness and spacing together, so the stair looks floating while staying within the rule.

  • Keep the gap between treads under 100 mm
  • Overlap each tread by at least 16 mm
  • Use riser bars or glass upstands if gaps are larger
  • Keep every rise in the flight the same

Guarding, balustrades and handrails

Any open side of a stair, and the landing edge above, needs guarding. For private stairs, guarding must be at least 900 mm high measured from the pitch line, and like the risers, must not allow a 100 mm sphere through any opening. Frameless glass balustrades are popular on floating stairs because they keep the open look while closing the side. Glass used in balustrades must be safety glass suited to the loads it will take, and is commonly toughened or toughened laminated.

Handrails help people use the stairs safely. Approved Document K expects a handrail on at least one side of stairs narrower than 1 metre and on both sides of wider stairs, set at a height between 900 mm and 1,000 mm above the pitch line. On a floating stair, the handrail is often a slim rail fixed to the wall.

Headroom and loft conversions

Headroom over the stair, measured vertically above the pitch line, should be at least 2 metres. Where a stair serves a loft conversion and there is not enough height, Approved Document K allows a reduced headroom of 1.9 metres at the centre line of the stair, with at least 1.8 metres at the side. This often decides where a floating stair can go, particularly under sloping ceilings or where the floor above is low.

If your proposed stair cannot meet headroom, the designer may change the position, the direction or the opening size in the floor above, which can involve trimming joists.

Scotland, Wales and listed buildings

In Scotland, stairs are covered by the Scottish Building Standards rather than Approved Document K, and a building warrant from the local authority is usually needed before a new or altered staircase is installed. The dimensions and guidance differ in places, so designs must be checked against the Scottish standards. Wales has its own versions of the Approved Documents, so check the Welsh guidance with Building Control. In a listed building, removing an original staircase or altering a stairwell can require listed building consent, which is separate from Building Regulations approval.

Questions people also ask

Are floating stairs legal in the UK?

Yes, provided they meet the Building Regulations. In England, that means following Approved Document K for rise, going, pitch, open risers, guarding and headroom, with the structure approved by Building Control. In Scotland, the Scottish Building Standards apply and a building warrant is usually needed.

Do floating stairs need a handrail?

Yes. Approved Document K expects a handrail on at least one side of a stair narrower than 1 metre and on both sides of wider stairs. The handrail should be between 900 mm and 1,000 mm above the pitch line. Open sides also need guarding at least 900 mm high.

Are open risers allowed on stairs in a family home?

Yes, for private stairs, as long as a 100 mm sphere cannot pass between treads and each tread overlaps the one below by at least 16 mm. Many family homes add riser bars or glass upstands to close gaps fully, which also helps if you have very young children.

Written and checked by the Floating Staircase Builders team. Read our editorial policy.